Input/Output Control System (IOCS) is any of several packages on early IBM entry-level and mainframe computers that provided low level access to records on peripheral equipment. IOCS provides functionality similar to File Control Processor (FCP)[1] in RCA 3301 Realcom Operating System and GEFRC[2] in GECOS.
Computers in the 1950s and 1960s typically dealt with data that were organized into records either by the nature of the media, e.g., lines of print, or by application requirements. IOCS was intended to allow Assembler language programmers to read and write records without having to worry about the details of the various devices or the blocking of logical records into physical records. IOCS provided the I/O support for several compilers.
In some cases[3] IOCS was designed to coexist with Simultaneous Peripheral Operations On-line (SPOOL)[4] software. The level of access is at a higher level than that provided by BIOS and BDOS in the PC world; in fact, IOCS has no support for character-oriented I/O. Versions of IOCS existed for the IBM 705 III[5], 1401/1440/1460, 1410/7010, 7070/7072/7074[6][7], 7080[8] and 7040/7044/7090/7094[9]. These systems heavily influenced the data management components of the operating systems[10] for the System/360; the name IOCS was carried through in DOS/360 through z/VSE[11], with a distinction between Logical IOCS (LIOCS) and Physical IOCS (PIOCS).
Although some technical details and nomenclature are different among the various IOCS packages, the fundamental concepts are the same. For concreteness, the discussion and examples in this article will mostly be in terms of 7070 IOCS[6][7]. Also, multiple continuation lines will be shown as ellipses (...) when they don't serve to illustrate the narrative.
Contents |
An IOCS program must do three things, each discussed in a subsection below.
For the 7070 these are done using 7070 Autocoder[12][13] declarative statements and Macro instructions.
IOCS supported several classes of I/O equipment
Some services offered by IOCS were not needed by all applications, e.g., checkpoints, label processing. An IOCS program must identify the particular devices types and services it uses. A 7070 IOCS program must specify one or more DIOCS[6](pp16-19)[12](pp22-25) statements:
GENERAL DIOCSgeneral parameters TAPE DIOCSD729,tape parameters DISK DIOCSD1301,disk parameters END DIOCS
These declarative statements identify index registers reserved for the use of IOCS, indicate channels used, indicate whether the program is to coexist with SPOOL and provide processing options. The END DIOCS statement causes the assembly of IOCS unless a preassembled version is requested. The first (general) form is omitted when the D729 firm is used.
In some other IOCS packages similar functions are provided by control cards.
An IOCS program must create a control block for each file, specifying information unique to the file. For 7070 IOCS these are entries in the 'File Specification Table for tape files, each of which is generated by a DTF[6](pp19-26)[12](pp26-28) statement, or separate control blocks generated by DDF [7](pp31-37)[12](pp29-30) or DUF[6](pp44-47)[12](pp31-33) statements.
DTF OUT FCHANNEL 2 ... ... DAFILE DDF IODEVICE 5 DREFMODE 4 ... ... DUF CONSFILE,1,4,CARDRDW,CARDIX,CONSEOF,CONSERR
The above code defines a tape file on channel 1 called OUT, a sequential 1301/1302 disk file called DAFILE and a card file called CONSFILE.
In some other IOCS packages similar functions are provided by control cards.
Any IOCS program must specify the actions that it wishes to perform. In 7070 IOCS this is done with processing macros.
OPEN CONSFILE,OUT LOOP GET CONSFILE PUT OUT B LOOP CONSEOF CLOSECONSFILE,OUT
In some other IOCS packages similar functions are provided by explicit subroutine calls.